Skip to product information
1 of 8

4Boats

SEAFLO 12V 800GPH 14B Timer-Sensing Automatic Low Profile Bilge Pump

SEAFLO 12V 800GPH 14B Timer-Sensing Automatic Low Profile Bilge Pump

Regular price £43.99 GBP
Regular price Sale price £43.99 GBP
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity

12V automatic time-sensing low-profile bilge pump

The SEAFLO SFBP1-G800-14B is a narrow, fully submersible automatic bilge pump for tight or awkward spaces. Instead of using a separate float switch, it briefly runs for approximately half a second every 2.5 minutes; if the motor senses water load, pumping continues. Its low-profile strainer can leave the bilge at approximately 10 mm when installed correctly.

Suitable boats and bilge arrangements

  • 12V sailing yachts, motorboats, RIBs and fishing boats with shallow or restricted bilge compartments.
  • Locations where a conventional upright pump and separate float switch will not fit.
  • Useful for unattended automatic nuisance-water removal, subject to correct wiring, battery capacity and regular testing.
  • Can be mounted horizontally or vertically with a 360-degree adjustable discharge.
  • Pump capacity is not selected by boat length alone; evaluate ingress risk, hose losses, alarm and redundancy.

Verified technical specification

Manufacturer model SFBP1-G800-14B
Series / control 14B automatic timer-sensing
Supply 12V DC
Nominal flow 800 GPH / approximately 3,028 LPH
Current 3.2 A
Maximum head 3.2 m / 10.5 ft
Water check cycle Approximately every 2.5 minutes; brief 0.5-second test run
Outlet options 19 mm, 25 mm and 29 mm straight hose barbs; 19 mm 90-degree elbow
Mounting / discharge Horizontal or vertical; 360-degree rotation
Features Check valve, anti-airlock design, removable strainer, stainless-steel shaft, tinned marine wiring
Standards stated by manufacturer CE, RoHS, ISO 8846 and ISO 8849

Check before ordering and installing

  • Confirm a 12V DC supply and account for the automatic test cycle when the boat is left unattended.
  • Choose the outlet and hose bore carefully; minimise lift, bends and restrictions because installed flow is lower than the open-flow rating.
  • Provide correctly rated fuse, marine cable and an accessible isolation arrangement in accordance with the wiring instructions.
  • Route the discharge above the loaded waterline and fit anti-siphon protection where required.
  • Keep the strainer accessible, test automatic operation regularly and use a separate high-water alarm for early warning of pump/system failure.
  • Package: one 14B pump with the manufacturer-listed outlet arrangements/check valve. Hose, fuse, alarm and through-hull are installation components.

Frequently asked questions

Does it need a separate float switch?

No. The 14B version performs its own timed water checks.

Why does the pump run briefly when the bilge appears dry?

That is the normal sensing cycle: it runs for about half a second every 2.5 minutes to check for water load.

Can it be used on a 24V system?

No. This model is 12V DC. Select the correct 24V version for a 24V boat.

Is 800 GPH the actual installed flow?

It is the nominal open-flow rating. Hose length, vertical lift, bends, valves and the through-hull reduce real flow.

View full details